Welcome to HouLin Intelligent Engineering Co., Ltd website!

Business

Scope of business

Hotline

+86-371-55976059

Tel:
+86-371-55976059

Address:
2403, Block B, Longzihu Zhengshang Xuefu Square, Zhengdong New District, Zhengzhou City

HouLin Intelligent Engineering Co., Ltd

Our company can provide maintenance and repair services for various large screw machines, centrifuges, and piston machines. Including major maintenance services for compressors, main engines, systems, etc.


In the field of central air conditioning maintenance technology, we have extensive contacts and exchanges with numerous domestic air conditioning manufacturers and trusted units of air conditioning technology, and can provide customers with timely and effective emergency repairs and any services needed for air conditioning systems.


The company has advanced maintenance equipment and instruments, such as refrigerant quantitative filling machine, refrigerant recovery machine, refrigerant composition analyzer, oven, refrigerator, central air conditioning pipeline cleaning machine, central air conditioning duct cleaning machine, etc., which can quickly identify the cause of faults and provide timely relief for users. The company has good partnerships with numerous domestic air conditioning spare parts suppliers, has established spare parts supply centers, and has stocked a large number of air conditioning spare parts. Can ensure the provision of genuine air conditioning parts to customers and quickly deliver the parts to them.


一、 Classification of central air conditioning maintenance and upkeep

1. Inspection and maintenance:

(1) Conduct various routine inspections in a planned manner based on equipment operation and customer needs;

(2) On site guidance for the owner's operators, explaining practical techniques for operating and maintaining the design unit;

(3) Provide various necessary value-added services;

(4) Provide professional opinions and improvement plans for the problems existing in the operation of the host and auxiliary equipment;


2. Preventive maintenance:

(1) Including the content provided for inspection and maintenance;

(2) Perform necessary preventive maintenance according to the manufacturer's recommendations;

(3) Preventive maintenance includes cleaning the copper tubes of the heat exchanger, analyzing and replacing the refrigeration oil, oil filter element, drying filter, etc;


3. Comprehensive maintenance and upkeep:

(1) A more comprehensive and thorough maintenance plan, including all routine inspections, value-added services, and emergency fault handling services;

(2) Responsible for all maintenance work and component replacement in case of equipment failure;


2、 Maintenance and upkeep of central air conditioning system


1. Air conditioning unit part


(1) Check whether the high and low pressure of the refrigerant in the refrigeration system of the air conditioning unit are normal;


(2) Check if there is any refrigerant leakage in the refrigeration system of the air conditioning unit and if refrigerant needs to be replenished;


(3) Check if the sound of the compressor running is normal;


(4) Check if the working current of the compressor is normal;


(5) Check if the working voltage of the compressor is normal;


(6) Check if the oil level and color of the compressor are normal;


(7) Check if the compressor oil pressure and temperature are normal;


(8) Check whether the wiring terminals of the air conditioning unit are loose;


(9) Check if the phase sequence protector of the air conditioning unit is functioning properly and if there are any missing phases;


(10) Check if the water flow protection switch is working properly;


(11) Check if the computer version, temperature sensing probe, and resistance are normal;


(12) Check if the air switch of the air conditioning unit is normal; Whether the communication contactor and thermal protector are in good condition;


2. Inspection of the wind system:


(1) Check if the air volume of the fan coil unit is normal;


(2) Check whether the return air filter of the fan coil unit has accumulated a layer of ash;


(3) Check if the outlet air temperature is normal;


3. Inspection of water system:


(1) Check the water quality of cooling and freezing water, and whether water replacement is needed;


(2) Check the impurities on the filter screen in the cooling and chilled water system, and clean the filter screen;


(3) Check for air in the water system and whether exhaust is needed;


(4) Check if the outlet water temperature is normal;


(5) Check the sound and operation of the water pump;


(6) Check whether the valve opens flexibly, whether there are rust spots, whether there are leaks, and other phenomena;


(7) Check the insulation system for cracking, damage, water leakage, and other phenomena;